The robust bed
The durable Videndo pro focuses on safety, comfort and hygiene and offers excellent value for money in every area. Its mechanical version is particularly suitable for psychiatric institutions. Various motorised versions are also available.
All additional information at a glance
MODULAR SYSTEM - Users can put together the right bed for the medical and economic requirements of their hospital or facility.
SECURITY - Easy-to-operate 3/4 safety side and full-length safety side for maximum protection are available as an option.
PSYCHIATRIC CARE - The mechanical version of the bed meets stringent safety requirements in psychiatric medical care. Head and footboards are optionally secured against removal. If required, additional securing brackets can be provided for the mattress base.
The following overview presents the technical data and equipment options for this model of bed. With a tailor-made configuration and visual design, and with suitable accessories, you can plan a bed that precisely matches your hospital’s requirements and interior design. Your area sales manager will be happy to inform you about all the possibilities.
Vivendo pro 80cm wide | Vivendo pro 90cm wide | |
---|---|---|
Mattress base in cm (mattress dimensions) in cm | 80 x 200 | 90 x 200 |
Bed extension in cm | 20 | 20 |
Ground clearance in cm ca. | 15 | 15 |
Safe working load in kg | 225 | 225 |
Total weight in kg | 130 | 130 |
Maximum weight of patient in kg ca. | 185 - 215 | 185 - 215 |
Tilting to Trendelenburg position in ° | 16 | 16 |
Tilting to reverse-Trendelenburg position in ° | 18 | 18 |
Mattress base height in cm (from - to) | 43 - 83 | 43 - 83 |
Backrest angle in ° | 70 | 70 |
Thigh rest angle in ° ca. | 82 (mechanical) 35 (electric) | 82 (mechanical) 35 (electric) |
Auto contour adjustment / Fowler position | ||
Manual CPR release of the backrest | ||
Electrically adjustable |
Vivendo pro 80cm wide | Vivendo pro 90cm wide | |
---|---|---|
Mattress base division in cm | 80/20/35/56 | 80/20/35/56 |
Backrest length compensation | 8 | 8 |
PP hygiene mattress base for belt system | ||
Radiolucence | ||
Full plastic (HPL) hygiene mattress base for belt system | ||
Wire mesh base (removable) | ||
Wire mesh base (fixed) | ||
4-section mattress base |
Vivendo pro 80cm wide | Vivendo pro 90cm wide | |
---|---|---|
No safety side | ||
Protective height of safety sides | 41 | 41 |
Full-length safety side attachable | ||
Tiltable safety side – 3/4 safety side |
Vivendo pro 80cm wide | Vivendo pro 90cm wide | |
---|---|---|
Integral castor Ø 150 mm | ||
Double castor Ø 150 mm | ||
5th castor (double castor Ø 125 mm) | ||
Castor braking, central |
Vivendo pro 80cm wide | Vivendo pro 90cm wide | |
---|---|---|
Standard handset | ||
Handset with selective locking function | ||
Locking box in the linen holder | ||
Lead-gel battery |
The Stiegelmeyer service commitment
Make an appointment directly with one of our specialist consultants.